-00846
Cause. The trace has failed. An internal Subsystem Control Point (SCP) trace error 
has been encountered.
Effect. SCP terminates.
Recovery. Restart SCP and report the error to your service provider. See If You Have 
to Call Your Service Provider on page B-2.
-00847
Cause. The TRACE target process responded incorrectly to a DEVICEINFO request.
Effect. The subsystem process terminates.
Recovery. Ask your system manager to restart the process for object-name; then 
retry the command. If this attempt fails, contact your service provider, as described 
under If You Have to Call Your Service Provider on page B-2.
-00848
Cause. A file-system error occurred when the TRACE collector attempted to initiate a 
trace.
Effect. SCF waits for the next command.
Recovery. Stop the current trace, start a new trace, and report this error to your 
service provider, as described under If You Have to Call Your Service Provider on 
page B-2.
-00849
Cause. The TRACE collector cannot be opened because a prior TRACE command is 
pending.
Effect. SCF waits for the next command.
Recovery. Wait a few seconds and retry the request.
subsystem {E|W}-00846 Internal Error: SCP trace error 
encountered.
subsystem {E|W}-00847 Trace target process object-name 
responded improperly to deviceinfo.
subsystem {E|W}-00848 Internal Error: Trace collector error.
subsystem {E|W}-00849 TRACE START is pending; retry trace 