SCF Reference Manual for G-Series RVUs (G06.24+)

SCF Error Messages
SCF Reference Manual for G-Series RVUs520413-004
B-63
Common Error Messages
-00862
Cause. The value specified by the TRACE command PAGES option is too large for
the existing trace file.
Effect. SCF waits for the next command.
Recovery. Retry the TRACE command using an appropriate (smaller) value for the
PAGES option.
-00983
Cause. A TRACE command modifier has not been supplied.
Effect. SCF waits for the next command.
Recovery. Retry the TRACE command with the appropriate modifier. Usually, this
error occurs because the TO clause has been omitted from the TRACE command
when the trace has been initiated.
-00984
Cause. A TRACE command contains conflicting modifiers.
Effect. SCF waits for the next command.
Recovery. Correct and retry the command.
-00985
Cause. An attempt to initiate a trace failed due to an error returned by the system
procedure call.
Effect. SCF waits for the next command.
Recovery. Refer to the Guardian Procedure Errors and Messages Manual for
recovery procedures.
subsystem {E|W}-00862 Existing TRACE FILE is not big enough
for PAGES specified.
subsystem {E|W}-00983 Trace command modifier required.
subsystem {E|W}-00984 Conflict trace modifiers: modifier-name
and modifier-name.
subsystem {E|W}-00985 SCP Trace collector failed; File System
error: err-num.