Using MIGSCF in Batch Mode
Following is the RPT03 conversion report for the OBEYIN conversion in Example 3 on
page C-20.
Using MIGSCF in Batch Mode
You can convert multiple command files of COUP or PUP commands to corresponding
files of SCF commands. The syntax is:
MIGSCF T5816D44 (31MAY97) 28MAR97 14:15 PM
Copyright Tandem Computers Incorporated, 1996
This software is an unsupported tool, and is Tandem Computers Incorporated
proprietary and confidential information.
Input file: \CB6.$DATA.PAT.OBEYIN
Output file: \CB6.$DATA.PAT.RPT03
Conversion mode: OBEY
New: COMMENT MIGSCF converted \CB6.$DATA.PAT.OBEYIN
on 28MAR97 14:15 PM
Copied: comment sample obey file
Old: PUP /IN PUPCMDS/
New: SCF /IN PUPCMDS/
* WARNING 656 * Command may refer to an unconverted command file.
Old: PUP CONSOLE, $0
New: COMMENT PUP CONSOLE, $0
* WARNING 205 * The PUP CONSOLE command is no longer supported. Use EMSDIST
instead.
Old: \REMOTE.PUP /IN MYFILE/
New: \REMOTE.SCF /IN MYFILE/
* WARNING 656 * Command may refer to an unconverted command file.
* WARNING 653 * Command invokes a remote copy of PUP.
Make sure the remote system is below the G-series.
Old: COUP INFO $SYSTEM, DETAIL
New: COMMENT COUP INFO $SYSTEM, DETAIL
* ERROR 367 * Missing object type.
File Conversion Summary:
Old commands read: 5
New commands written: 6
MIGSCF / IN filelist [ , OUT rptfile ] / -B [S]