SCF Reference Manual for G-Series RVUs (G06.27+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-005
B-3
Table-Driven PM Error Messages
6. Close the log file:
-> LOG
Table-Driven PM Error Messages
The following error messages are produced in response to errors encountered by
table-driven product modules (PMs). The table-driven product module error numbers
begin at 00001. Note that each error message is displayed here with a prefix of
“TABLPM”, followed by the error number and the error text.
00001
Cause. A required attribute has not been entered by the user.
Effect. SCF waits for the next command.
Recovery. Retry the command using the correct attribute set.
00002
Cause. A particular attribute has been entered more than once.
Effect. SCF waits for the next command.
Recovery. Retry the command after removing duplicate attributes.
00003
Cause. The subsystem table and SCF product module versions do not match.
Effect. SCF waits for the next command.
Recovery. Locate the subsystem table (file code type 0) that matches the version of
the SCF product module (ZTBLSCF), and copy it to the $SYSTEM.SYSTEM or
$SYSTEM.SYSnn subvolume. Then retry the command.
TABLPM 00001 Required attribute is missing.
TABLPM 00002 Duplicate attribute.
TABLPM 00003 Incompatible versions between subsystem table
(version-number) and TABLPM PM (version-number).