SCF Reference Manual for G-Series RVUs (G06.27+)

SCF Error Messages
SCF Reference Manual for G-Series RVUs520413-005
B-17
SCF Error Messages
20085
Cause. The specified item can contain only number or fewer characters.
Effect. SCF waits for the next command.
Recovery. Use the FC command to reenter the command with a shorter item name.
20086
Cause. The value portion of the PARAM command can contain only number or fewer
characters.
Effect. SCF waits for the next command.
Recovery. Retry the PARAM command with a shorter value.
20087
Cause. The first G-relative memory location has been altered. This should never
happen under normal conditions. Usually this is caused by an uninitialized pointer.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
20088
Cause. You entered an invalid TRACE command. When starting a trace, the TO
option must be specified. When stopping a trace, the STOP option must be specified.
Effect. SCF waits for the next command.
Recovery. Specify either the TO file-spec option to initiate a trace operation or the
STOP option to stop a trace operation.
SCF 20085 item can be no more than number characters long.
SCF 20086 The maximum size of a param value is number
characters.
SCF 20087 Internal Error: Memory location zero overwritten.
SCF 20088 Either the STOP or TO option must be specified in
each TRACE command.