SCF Reference Manual for G-Series RVUs (G06.27+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-005
B-43
Common Error Messages
Recovery. Report to your service provider that this message is too long for SCF to
display. The message should be reworded to be less than or equal to 1024
characters.
20348
Cause. An internal buffer has overflowed because more than 42 subsystems are
configured. This message might be displayed when you enter the SCF HELP
command; the list of subsystems displayed is limited to 42.
Effect. SCF does not execute any commands for more than 42 subsystems, as
displayed by the SCF HELP command. To display a complete list of SCF product
modules on the system, type the following command at the TACL prompt:
> FILEINFO $SYSTEM.SYSTEM.Z*EXP
The inaccessible subsystems are listed at the end of the alphabetic list produced by
the FILEINFO command.
Recovery. Either (1) delete enough unused product module files to get below 42 or (2)
move some SCF product modules to another location by using the
PARAM^SCF^PM^LOC command described on page 4-19.
20349
Cause. You entered a TRACE command with a PREALLOCATE or
NOPREALLOCATE option on a system whose SCP version is earlier than D40. These
options are supported only on systems whose SCP version is D40 or later.
Effect. SCF waits for the next command.
Recovery. Reenter the TRACE command without the PREALLOCATE or
NOPREALLOCATE option.
Common Error Messages
The following error messages are common to all subsystems. These error messages
have a negative-value error number in the range from -00001 through -00999. They
are reported through SCF. Each error message is preceded by the name of the
subsystem in which the error is encountered, a single-character type code (E for error
or W for warning), and the error number.
SCF 20348 Number of subsystems exceed the buffer space
SCF 20349 SCP version is less than D40. Trace parameter param
is ignored