SCF Reference Manual for G-Series RVUs (G06.27+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-005
B-45
Common Error Messages
-00005
Cause. A command has been issued that is unknown to the subsystem that owns the
specified object.
Effect. SCF waits for the next command.
Recovery. Refer to the SCF reference manual for a specific subsystem for information
about what commands are supported by that particular subsystem.
-00006
Cause. The command sequence is invalid. A command has been issued and cannot
be executed because of the current activity or state of object-name.
Effect. SCF waits for the next command.
Recovery. This can be a warning or an error. Refer to the SCF reference manual for
a specific subsystem for information about how that particular subsystem handles this
object’s command sequence.
-00007
Cause. A command has expired before a response was received by the Subsystem
Control Point (SCP).
Effect. SCF waits for the next command.
Recovery. Retry the command after needed resources have become available.
-00008
Cause. A command has been issued, and the byte-count read by the file-system
procedure (for example, READUPDATE) is smaller than the used-length value in the
command buffer.
Effect. SCF terminates.
subsystem {E|W}-00005 Command is not supported by this
subsystem.
subsystem {E|W}-00006 Command sequence invalid for object-
name.
subsystem {E|W}-00007 Command timed out on object-name.
subsystem {E|W}-00008 Internal error: SPI buffer larger than
expected for object-name.