SCF Reference Manual for G-Series RVUs (G06.27+)

SCF Error Messages
SCF Reference Manual for G-Series RVUs520413-005
B-49
Common Error Messages
-00021
Cause. A SWITCH command has been issued against a resource unknown to the
named subsystem.
Effect. SCF waits for the next command.
Recovery. Check for the correct configuration and retry the command against the
proper resource.
-00022
Cause. A sensitive command has been entered by a user unauthorized to issue such
a command. Unless the named subsystem has assumed control over command
security, SCP generates this error.
Effect. SCF waits for the next command.
Recovery. If possible, acquire the proper security and retry the command.
-00023
Cause. An error occurred having to do with a call to an SPI procedure.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider
on page B-2,
save pertinent information and contact your service provider.
-00024
Cause. The subsystem ID specified (using a call to SSINIT) in the request is invalid.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
subsystem {E|W}-00021 Resource text is not configured for
object-name.
subsystem {E|W}-00022 Security violation for object-name.
subsystem {E|W}-00023 Internal Error: SPI error err-num text
on call-name (Tnm: token-number).
subsystem {E|W}-00024 Internal Error: Invalid subsystem ID:
Owner: subsystem Number: subsystem-number Version: version-
number.