SCF Reference Manual for G-Series RVUs (G06.27+)
SCF Error Messages
SCF Reference Manual for G-Series RVUs—520413-005
B-60
Common Error Messages
-00850
Cause. The version of the subsystem control point (SCP) is not compatible with that of
the TRACE collector.
Effect. SCF waits for the next command.
Recovery. Use versions of the SCP and the TRACE collector that are part of the
same RVU.
-00851
Cause. The internal table of the TRACE collector is full.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
-00852
Cause. The parameter parameter-name supplied to the TRACE command is
incorrect.
Effect. SCF waits for the next command.
Recovery. Retry the TRACE command using a valid parameter.
-00853
Cause. The TRACE collector has encountered an internal error.
Effect. SCF terminates.
Recovery. As described under If You Have to Call Your Service Provider on page B-2,
save pertinent information and contact your service provider.
subsystem {E|W}-00850 Version Incompatible between SCP and
TRACE collector.
subsystem {E|W}-00851 Internal Error: The TRACE collector's
copy table is full.
subsystem {E|W}-00852 Incorrect trace parameter: parameter-
name.
subsystem {E|W}-00853 Internal Error: The TRACE collector’s
phandle is bad; Detail = number.