SCF Reference Manual for the Kernel Subsystem
11 <-DOWN
12 <-DOWN
13 <-DOWN
15 <-DOWN
Y-FABRIC
T0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
FROM
0 UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA
1 UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA
2 UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA
3 UP UP UP UP UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA UNA
4 <-DOWN
5 <-DOWN
6 <-DOWN
7 <-DOWN
8 <-DOWN
9 <-DOWN
10 <-DOWN
11 <-DOWN
12 <-DOWN
13 <-DOWN
14 <-DOWN
15 <-DOWN
• You can also use the VERSION command to display the operating system version of the
ServerNet network. For example
-> VERSION SERVERNET $ZSNET
VERSION SERVERNET \DELUX.$ZSNET: SERVERNET (MGR) - T1085F40 - (31AUG99) - (28MAY99)
Identifying ServerNet Hardware Failures
These hardware failures can affect a ServerNet X or Y fabric:
• There is no access to a processor multifunction (PMF) customer-replaceable unit (CRU).
• A ServerNet expansion board (SEB) or modular ServerNet expansion board (MSEB) is failing.
Before repairing such a failure, use the STATUS SERVERNET command to verify that all other
ServerNet connections are accessible.
Example 1
If the STATUS SERVERNET display looks like this example, there is no access to the PMF CRU
containing processor 1. The status conditions indicating that there are access problems are shown
in bold.
-> STATUS SERVERNET $ZSNET
66 Managing the ServerNet Network