SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11- 7
Displaying Storage Adapter Status Information
Example of a Detailed INFO FCSA Adapter Report
-> INFO ADAPTER $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1, DETAIL
Displaying Storage Adapter Status Information
The STATUS ADAPTER Command (page 14-138) displays current information about
storage adapters and connected devices:
•
To display status of the adapter in the PMF CRU in group 1, slot 50:
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
The display is shown and explained under Example of a STATUS PMF ADAPTER
Report on page 11-8.
•
To display detailed status of the same adapter in the PMF CRU:
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50, DETAIL
The display is shown and explained under Example of a Detailed STATUS PMF
ADAPTER Report on page 11-9.
•
To display status of the adapter in the IOMF CRU in group 11, slot 50:
-> STATUS ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
The display is shown and explained under Example of a STATUS IOMF ADAPTER
Report on page 11-11.
•
To display detailed status of the same adapter in the IOMF CRU:
-> STATUS ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50, DETAIL
STORAGE - Detailed Info ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
ServerNet Addressable Controllers:
SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-2.SLOT-1:
Configured Devices ( group: 11, module: 2 ):
Slot Type Name Primary Backup Device ID
CPU CPU /Port Name Lun
1 DISK $PT00-B 3 2 50060E8003506012 0
1 DISK $PT01-B 3 2 50060E8003506012 1
1 DISK $PT02-B 3 2 50060E8003506012 2
1 DISK $PT03-B 3 2 50060E8003506012 3
SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-2.SLOT-1:
Configured Devices ( group: 11, module: 2 ):
Slot Type Name Primary Backup Device ID
CPU CPU /Port Name Lun
1 DISK $PT00-M 3 2 50060E8003506011 0
1 DISK $PT01-M 3 2 50060E8003506011 1
1 DISK $PT02-M 3 2 50060E8003506011 2
1 DISK $PT03-M 3 2 50060E8003506011 3