SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage 
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11- 8
Displaying Storage Adapter Status Information
The display is shown and explained under Example of a Detailed STATUS IOMF 
ADAPTER Report on page 11-12.
•
To display status of the 6760 ServerNet device adapter in group 11, slot 51:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
The display is shown and explained under Example of a STATUS SNDA 
ADAPTER Report on page 11-13.
•
To display detailed status of the same 6760 ServerNet device adapter:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51, DETAIL 
The display is shown and explained under Example of a Detailed STATUS SNDA 
ADAPTER Report on page 11-14.
Example of a STATUS PMF ADAPTER Report
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50 
STORAGE - Status ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
 Location Status   POST  Power-1 Power-2 SACs
 (1,1,50) PRESENT  PASSED ON  ON 3
Explanation of Fields
Location the physical location of the adapter (group, module, slot). 
Status shows whether the adapter is present. 
POST shows whether the power-on self-test (POST) passed. 
Power-1 shows whether power rail 1 has power on. 
Power-2 shows whether power rail 2 has power on. 
SACs the number of SACs present in the adapter (three SACs for a PMF 
CRU or IOMF CRU, up to four SACs for a ServerNet/DA). 