SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11-10
Displaying Storage Adapter Status Information
Explanation of Fields
Adapter Type the type of adapter. Possible values: PMF, PMF2, IOMF, IOMF2,
SNDA
Location the location of the adapter (group, module, slot).
Number of
SACs
the number of SACs present in the adapter (3 SACs for a PMF
CRU or IOMF CRU, up to 4 SACs for an SNDA).
Part ID the vendor number stored in the adapter.
POST Result shows whether the power-on self-test (POST) passed.
Power-1 shows whether power rail 1 has power on.
Power-2 shows whether power rail 2 has power on.
Revision Level the revision level stored in the adapter.
Status shows whether the adapter is present.
Tracking
Number
the vendor ID stored in the adapter.
Vendor ID the manufacturer of the adapter (when available).
ServerNet Addressable Controllers:
SAC Number the SAC within the adapter.
Firmware the part number of the firmware.
POST Result shows whether the power-on self-test (POST) passed.
SAC Type the protocol type of the SAC.
SAC SSCI ID the SAC ID, which is used to locate a specific SAC in the adapter.
Side shows whether the SAC is accessed by the X fabric or Y fabric.
Slots 50, 51, and 53 are on the X fabric. Slots 52, 54, and 55 are
on the Y fabric.
Status shows whether the SAC is present.
Configured Devices (group: n, module: n):
Slot for internal disks, this is the slot number of the device. For 45xx
disks or tape drives, this is the location of the adapter controlling
the 45xx disk or tape drive.
Name the configured name of the device accessed by this SAC.