SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage 
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11-15
Displaying Storage Adapter Status Information
Example of a STATUS FCSA ADAPTER Report
 -> STATUS ADAPTER $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
See Explanation of Fields on page 11-8.
Example of a STATUS FCSA ADAPTER, SACS
-> STATUS ADAPTER $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1, SACS
Location Status  POST  Power-1 Power-2 SACs
(11,2,1) PRESENT  PASSED ON  ON  2
STORAGE - Detailed Status ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
 Adapter Type..... FCSA
 Flash Boot....... T0612G06 Flash Update Active.... Done
 Flash Firmware... T0630G06 Flash Update Result.... Init
 Location......... (11,2,1) Number of SACs......... 2
 Part ID.......... 526217-001 POST Result............ PASSED
 Power-1.......... ON  Power-2................ ON
 Revision Level... A01-01  Status................. PRESENT
 Tracking Number.. MP0008  Vendor ID..............
 ServerNet Addressable Controllers:
 SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-2.SLOT-1:
 SAC Number..... 1  Firmware.......... T0630G06
 POST Result.... PASSED  SAC SCSI ID.......
 SAC Type....... FC  Side.............. Both
 Status......... PRESENT
 Connection..... F port  Node Name......... 20060B00001CE5F8
 Port Id........ 65792  Port Name......... 50060B00001CE5F8
 SAC State...... Ready  SAC Subtype....... 1
 SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-2.SLOT-1:
 SAC Number..... 2  Firmware.......... T0630G06
 POST Result.... PASSED  SAC SCSI ID.......
 SAC Type....... FC  Side.............. Both
 Status......... PRESENT
 Connection..... Loop  Node Name......... 20060B00001CE5FA
 Port Id........ 1  Port Name......... 50060B00001CE5FA
 SAC State...... Ready   SAC Subtype....... 1
Explanation of 
Fields
Flash Boot is the name of the flash boot file.
Firmware is the name of the flash firmware file
Flash Update 
Active
indicates the status of the flash update operation
Flash Update 
Result
indicates the state resulting from the flash update operation
ServerNet Addressable Controllers: 