SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage 
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11-16
Displaying Storage Adapter Status Information
For an explanation of fields, see pages 11-10 and 11-18.
Example of a STATUS FCSA ADAPTER, SERVERNET Report
-> STATUS ADAPTER $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1, SERVERNET
Connection indicates the Fibre Channel connections type.
Port Id designates the controller identifier from the Fabric Switch Name 
Server. (For the Loop connection type, Port Id is equal to 
controller AL_PA.)
SAC State indicates the state of the SAC:
INIT  Initial state, not downloaded
READY  Downloaded, ready to accept commands
NO-HW  No hardware, SAC not installed
DOWNLOADING Downloading
FW_RR  SAC firmware error 
HW_ERR  SAC hardware error
MAX_DOWNLOAD Downloads exceed limit
Node Name designates the worldwide name (WWN) of the controller node.
Port Name designates the worldwide name (WWN) of the controller port.
SAC Subtype indicates the type of SAC. The numeral one (1) indicates a two-
port, 2 GB Fibre Channel SAC.
STORAGE - ServerNet Status ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
 CPU| 0  1 2 3 4 5 6 7  8 9  10 11  12 13 14 15
 fabric |
 -------+-----------------------------------------------------------------
 X-from | UNK UNK UP UP DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN
 X-to | UNK UNK UP UP DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN
 -------+-----------------------------------------------------------------
 Y-from | UNK UNK UP UP DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN
 Y-to | UNK UNK UP UP DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN DWN
Explanation of Fields
x-from  indicates the ServerNet X-fabric status on the link 
from each CPU to the specified FCSA.
y-to indicates the ServerNet Y-fabric status on the link 
to each CPU from the specified FCSA.