SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing ServerNet Storage 
Adapters
SCF Reference Manual for the Storage Subsystem—529937-007
11-18
Displaying Storage Adapter Status Information
Example of a Detailed STATUS FCSA ADAPTER Report
-> status adapter $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1, DETAIL
STORAGE - Detailed Status ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
 Adapter Type..... FCSA
 Flash Boot....... T0612G06 Flash Update Active.... Done
 Flash Firmware... T0630G06 Flash Update Result.... Init
 Location......... (11,2,1) Number of SACs......... 2
 Part ID.......... 526217-001 POST Result............ PASSED
 Power-1.......... ON  Power-2................ ON
 Revision Level... A01-01  Status................. PRESENT
 Tracking Number.. MP0008  Vendor ID..............
 ServerNet Addressable Controllers:
 SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-2.SLOT-1:
 SAC Number..... 1  Firmware.......... T0630G06
 POST Result.... PASSED  SAC SCSI ID.......
 SAC Type....... FC  Side.............. Both
 Status......... PRESENT
 Connection..... F port  Node Name......... 20060B00001CE5F8
 Port Id........ 65792  Port Name......... 50060B00001CE5F8
 SAC State...... Ready  SAC Subtype....... 1
 Configured Devices ( group: 11, module: 2 ):
  Slot Name   State  Substate  Primary  Backup
        PID  PID
  1 $PT00-B  STARTED   2,272  3,264
  1 $PT01-B  STARTED   3,283  2,273
  1 $PT02-B  STARTED   3,282  2,274
 SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-2.SLOT-1:
 SAC Number..... 2  Firmware.......... T0630G06
 POST Result.... PASSED  SAC SCSI ID.......
 SAC Type....... FC  Side.............. Both
 Status......... PRESENT
 Connection..... Loop  Node Name......... 20060B00001CE5FA
 Port Id........ 1  Port Name......... 50060B00001CE5FA
 SAC State...... Ready  SAC Subtype....... 1
 Configured Devices ( group: 11, module: 2 ):
  Slot Name   State  Substate  Primary  Backup
        PID  PID
  1 $PT00-M *STARTED   2,272  3,264
  1 $PT01-M *STARTED   3,283  2,273
  1 $PT02-M *STARTED   3,282  2,274
Explanation of Fields
Flash Boot is the name of the flash boot file.
Firmware is the name of the flash firmware file
Flash Update Active indicates the status of the flash update operation
Flash Update Result indicates the state resulting from the flash update operation
ServerNet Addressable Controllers: 
Connection indicates the Fibre Channel connections type.