SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Configuring and Managing Open SCSI Devices
SCF Reference Manual for the Storage Subsystem—529937-007
12-2
Configuring Paths for Open SCSI Devices
Configuring Paths for Open SCSI Devices 
The values you specify when configuring an Open SCSI device vary depending on the 
type of connection and the NonStop server model. For example, the valid ranges for 
group, module, and slot of an Open SCSI device connected to an FCSA on an Integrity 
NonStop NS-series server differ from those of an Open SCSI device connected to an 
ServerNet/DA on a NonStop S-series server. 
Table 12-1, Open SCSI Path Attributes, on page 12-2 lists the possible attribute values 
for the different types of Open SCSI connections.
Note. When a NonStop S-series I/O enclosure is attached to an Integrity NonStop NS-series 
system, the enclosure retains the same group number it had on the NonStop S-series system. 
However, if the appropriate port for the group number is not available on the Integrity NS-series 
server, you must change the group number of the I/O enclosure. For more information, see the 
NonStop NS-Series Hardware Installation Manual. 
Table 12-1. Open SCSI Path Attributes
SNDA (S-pic) 
Connection
PMF/IOMF 
Connection 
FCSA Connection 
NonStop NS-series
LOCATION
 Group 1-89 1-89 110-125 
 Module 1 1 2-3 (IOAM)
 Slot 51-54 50 or 55 1-5 (FCSA)
SAC 1-4 3 1-2
SCSIID 0-15 (except 6-7) 0-15 (except 6-7) NA
PORTNAME NA NA 64-bit WWN
LUN 0-7 0-7 0-32767
LOCATION represents PRIMARYLOCATION and BACKUPLOCATION.
SAC represents PRIMARYSAC and BACKUPSAC.
PORTNAME represents PRIMARYPORTNAME and BACKUPPORTNAME.