SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)

Configuring and Managing Open SCSI Devices
SCF Reference Manual for the Storage Subsystem529937-007
12-4
Displaying Configuration Information
Examples of Detailed INFO SCSI Reports
This example shows an INFO DETAIL report for an Open SCSI device connected to an
IOMF CRU:
-> INFO SCSI $S11500, DETAIL
This example shows an INFO DETAIL report for an Open SCSI Fibre Channel device
connected to an FCSA on an Integrity NonStop NS-series server:
-> INFO SCSI $EXT8, DETAIL
STORAGE - Detailed Info SCSI configuration \COMM.$S11500
I/O Process Information:
*BackupCpu............................. 0
*HighPin............................... ON
*PrimaryCpu............................ 1
*Program............................... $SYSTEM.SYSTEM.TDSCSI
*RecSize............................... 4096
*StartState............................ STARTED
SCSI Device Settings:
*MaxOpens.............................. 4
*NumIO................................. 8
*StructAreaSize........................ 24
*TraceBufLen........................... 33
*TraceLevel............................ 65535
Primary Path Info:
Adapter Name.......................... $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
Adapter Location (group,module,slot).. (11,1,50)
*LUN................................... 0
SAC Name.............................. IOMF.SAC-3.GRP-11.MOD-1.SLOT-50
SAC Number............................ 3
*SCSI ID / Portname.................... 0
STORAGE - Detailed Info SCSI configuration \NSCOMM.$EXT8
I/O Process Information:
*BackupCpu............................. 1
*HighPin............................... ON
*PrimaryCpu............................ 1
*Program............................... $SYSTEM.SYSTEM.TDSCSI
*RecSize............................... 4096
*StartState............................ STARTED
SCSI Device Settings:
*MaxOpens.............................. 4
*NumIO................................. 8
*StructAreaSize........................ 24
*TraceBufLen........................... 33
*TraceLevel............................ 65535
Primary Path Info:
Adapter Name.......................... $ZZSTO.#FCSA.GRP-111.MOD-2.SLOT-5
Adapter Location (group,module,slot).. (111,2,5)
*LUN................................... 0
SAC Name.............................. FCSA.SAC-1.GRP-111.MOD-2.SLOT-5
SAC Number............................ 1
*SCSI ID / Portname.................... 2000003E00452211