SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-007
B-18
Storage Subsystem Error Messages
00047
Cause. You issued a START or PRIMARY command targeting a processor or set of
processors that were not running.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reload the processors or change the configuration and reissue the
command.
00048
Cause. You issued an ADD or ALTER command, specifying a location that does not
have its corresponding adapters installed.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Correct the command to use locations that are available.
00049
Cause. The command failed because of an internal error. The storage subsystem
manager experienced an error condition while accessing a helper server.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Restart the storage subsystem manager and retry the command. If the
problem persists, contact your service provider.
00050
command
is the command you specified.
errnum
is the POOL argument error number.
Cause. The ALTER command was issued with a storage pool attribute that is in
conflict with the current configuration or was invalid or missing.
STORAGE 00047 CPUs not running.
STORAGE 00048 Required adapter not present for location.
STORAGE 00049 Command failed.
STORAGE 00050 command failed. POOL argument error: errnum