SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-007
B-24
Storage Subsystem Error Messages
00066 
cmd 
is the command you specified. 
sacpath 
is the path of the ServerNet addressable controller (SAC) specified in the 
command. 
Cause.  The indicated SAC did not pass the power-on self-test (POST).
Effect. The command is not executed. SCF waits for the next command. 
Recovery. Contact your service provider. See If You Have to Contact Your Service 
Provider on page B-1.
00067 
cmd 
is the command you specified. 
 sacpath 
is the path of the ServerNet addressable controller (SAC) specified in the 
command. 
Cause. The type of the SAC specified in the command does not match the SAC type 
in the PRIMARYSAC location. 
Effect. The command is not executed. SCF waits for the next command. 
Recovery. Resolve the cause of the failure and reissue the command. 
00068 
cmd 
is the command you specified. 
 sacpath 
STORAGE 00066 cmd failed. POST did not succeed for sacpath. 
STORAGE 00067 cmd failed. Mismatched SAC type in sacpath.
STORAGE 00068 cmd failed. Wrong CRU type for device in 
sacpath.