SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)

Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem529937-007
B-25
Storage Subsystem Error Messages
is the path of the ServerNet addressable controller (SAC) specified in the
command.
Cause. The device type of the device specified in the command does not match the
device type of the primary device.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Verify the device specified in the command is the same type as the primary
device. (For example, you are trying to mirror an internal disk with a 45xx disk.) Then,
reissue the command.
00069
cmd
is the command you specified.
sacpath
is the path of the ServerNet addressable controller (SAC) specified in the
command.
Cause. The indicated command specified a combination of paths and processors that
is not supported by the I/O process (IOP).
Effect. The command is not executed. SCF waits for the next command.
Recovery. Resolve the cause of the failure and reissue the command.
00070
cmd
is the command you specified.
sacpath
is the path of the ServerNet addressable controller (SAC) specified in the
command.
Cause. The device specified for the indicated path is already configured for another
process.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Resolve the cause of the failure and reissue the command.
STORAGE 00069 cmd failed. sacpath violates IOP placement.
STORAGE 00070 cmd failed. sacpath is already in use.