SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)

Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem529937-007
B-37
Storage Subsystem Error Messages
00102
Cause. Requested operation failed due to a file system error.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Check the returned file system error to determine what to do next.
00103
Cause. An action is currently in progress for the object name you specified.
Effect. The command is rejected.
Recovery. Wait a few seconds and try the command again.
00104
Cause. You tried to perform an action that is invalid for the specified disk volume.
Effect. SCF waits for the next command.
Recovery. To determine why the command failed, consult the accompanying error
message.
00105
Cause. The command failed when trying to send a command to the I/O process.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Collect the information in the error text and contact your service
representative for further assistance.
STORAGE E00102 Requested operation failed due to a file
system error.
STORAGE E00103 Command rejected because there's another
action pending for the specified object name.
STORAGE E00104 Not allowed: the specified action is invalid
for the specified disk volume
STORAGE E00105 I/O operation failed.