SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-007
B-44
Storage Subsystem Error Messages
2. Remove the command from the SCF command file.
01012 
volname
is the name of the volume that you specified in the command. 
Cause. You issued the CONTROL DISK, REPLACEBOOT command in noninteractive 
mode. The CONTROL DISK, REPLACEBOOT command is available only in 
interactive mode. In interactive mode, you are prompted to verify the operation. 
Effect. The REPLACEBOOT operation is not performed. SCF waits for the next 
command. 
Recovery.  
1. Start SCF and reissue the command from the SCF prompt. 
2. Remove the command from the SCF command file. 
01013 
Cause. You issued the CONTROL DISK, REPLACEBOOT command in noninteractive 
mode. The CONTROL DISK, REPLACEBOOT command is available only in 
interactive mode. In interactive mode, you are prompted to verify the operation.
Effect. The REPLACEBOOT operation is not performed. SCF waits for the next 
command.
Recovery.
1. Start SCF and reissue the command from the SCF prompt. 
2. Remove the command from the SCF command file. 
01014 
sectoraddress
is the address of the sector that you attempted to spare.
STORAGE 01012 The CONTROL DISK, REPLACEBOOT operation will 
OVERWRITE the existing bootstrap on volname.
STORAGE 01013 The CONTROL DISK, REPLACEBOOT operation can 
leave one of the disk paths in a HARDDOWN substate.
STORAGE 01014 LSA sectoraddress passed controller 
defectiveness testing and was not spared.