01033
Cause. An automatic disk rename took place. This can happen when a new disk is
installed in a slot and the label has a name that does not match the name in the
system configuration database. The storage subsystem detects this name change,
updates the database, and issues this message.
Effect. The system configuration database is updated with the new name. SCF waits
for the next command.
Recovery. Informational message only; no corrective action is required.
01034
devname
is the name of the device you specified in the command.
Cause. The disk revive operation was restarted in response to an SCF START DISK
command.
Effect. The revive operation continues from the point where it was suspended.
Recovery. Informational message only; no corrective action is required.
01035
cmd
is the SCF command you specified.
attribute
is the attribute that you specified with an invalid value.
Cause. You specified an invalid value for the attribute in the command.
Effect. The command is not executed. SCF waits for the next command.
STORAGE 01033 Disk old-name changed name to new-name.
STORAGE 01034 Resuming suspended disk revive on devname.
STORAGE 01035 cmd failed. Invalid attribute value in: