SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-007
B-54
Storage Subsystem Error Messages
Recovery. You have the choice to start the disk regardless of the label discrepancy. In 
same cases, you have to choose whether to start the primary or mirror half of the disk.
01040 
Cause. Both locations for a mirrored disk volume target the same SCSI bus.
Effect.  The command is not executed. SCF waits for the next command.
Recovery. Correct the command to use different SCSI buses for the primary and 
mirror halves of the mirrored disk volume.
01041 
Cause. The STOPOPENS command was issued.
Effect.  In interactive mode, you are prompted to confirm the operation. In 
noninteractive mode the operation is performed.
Recovery. Informational message only; no corrective action is required.
01042 
Cause. You issued a STOPOPENS command for $SYSTEM.
Effect.  In interactive mode, you are prompted to confirm the operation. In 
noninteractive mode the operation is performed.
Recovery. Copy the SCF program to a disk other than $SYSTEM before continuing. 
Do not exit SCF without having another copy on another disk.
01043 
name 
is the name of the disk that has open files.
num
STORAGE 01040 Both slots target the same SCSI chain. 
STORAGE 01041 STOPOPENS prevents files from being opened
STORAGE 01042 STOPOPENS prevents files from being opened on 
$SYSTEM
STORAGE 01043 Operation succeeded, disk name contains num 
open files