SCF Reference Manual for the Storage Subsystem (G06.24+, H06.03+)
Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-007
B-68
Storage Subsystem Error Messages
09017 
Cause. You issued a command that specifies an ANTLOCATION for a disk that will 
not accept the file because PHYSVOLSELECT OFF disallows writing the file to that 
disk. 
Effect.  The command is not executed. SCF waits for the next command.
Recovery. Reissue the command to a volume that will accept the file or change the 
value of the PHYSVOLSELECT attribute of the disk you used in the command. 
09018 
name 
is the name of the catalog disk volume you used in the command you issued. 
Cause. The catalog disk volume that you specified in the command does not reside in 
a storage pool.
Effect.  The command is not executed. SCF waits for the next command.
Recovery. Put the catalog disk volume into a storage pool and reissue the command.
09019 
name 
is the name of the Storage Management Foundation (SMF) process. 
Cause. The command you issued requires that the SMF process be in the STARTED 
state. 
Effect.  The command is not executed. SCF waits for the next command.
Recovery. Start the process and reissue the command. 
STORAGE 09017 Invalid ANTLOCATION. The volume has 
PHYSVOLSELECT OFF. 
STORAGE 09018 SMF dependency failure: Catalog disk volume 
name is not in a pool.
STORAGE 09019 SMF dependency failure: SMF process name is not 
in the STARTED state. 