SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)
Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem—529937-008
11- 3
Displaying Storage Adapter Configuration
Information
Example of an INFO PMF ADAPTER Report
-> INFO ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Example of a Detailed INFO PMF ADAPTER Report
-> INFO ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50, DETAIL
This report shows that the storage adapter in a PMF CRU :
•
Has mirrored disks on SAC 1 and SAC 2
STORAGE - Info ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Location Access List
(1,1,50) 0,1
Explanation of Fields
Location is where the storage adapter is located (group, module, and slot).
Access List is the numbers of the processors configured to access this storage
adapter.
STORAGE - Detailed Info ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Access List................... 0,1
Location (Group,Module,Slot).. (1,1,50)
ServerNet Addressable Controllers:
SAC \COMM.$ZZSTO.#PMF.SAC-1.GRP-1.MOD-1.SLOT-50:
Configured Devices ( group: 1, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID Lun
2 DISK $OPER-MB 0 1 4 0
4 DISK $MAG1-MB 1 0 5 0
8 DISK $AOL1-MB 0 1 9 0
12 DISK $SYSTEM-MB 0 1 0 0
14 DISK $DSMSCM-MB 0 1 1 0
16 DISK $AUDIT-MB 0 1 2 0
18 DISK $NEWSYS-MB 0 1 3 0
SAC \COMM.$ZZSTO.#PMF.SAC-2.GRP-1.MOD-1.SLOT-50:
Configured Devices ( group: 1, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID Lun
1 DISK $OPER-P 0 1 4 0
3 DISK $MAG1-P 1 0 5 0
7 DISK $AOL1-P 0 1 9 0
11 DISK $SYSTEM-P 0 1 0 0
13 DISK $DSMSCM-P 0 1 1 0
15 DISK $AUDIT-P 0 1 2 0
17 DISK $NEWSYS-P 0 1 3 0
SAC \COMM.$ZZSTO.#PMF.SAC-3.GRP-1.MOD-1.SLOT-50:
Configured Devices ( group: 1, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID
50 TAPE $DL2 0 1 5