SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)
Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem—529937-008
11- 4
Displaying Storage Adapter Configuration
Information
•
Has a tape drive on SAC 3
Example of an INFO IOMF ADAPTER Report
-> INFO ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
See Explanation of Fields, on page 11-3.
Explanation of Fields
Access List the numbers of the processors that can access this storage
adapter.
Location (Group,
Module, Slot)
where the storage adapter is located.
ServerNet Addressable Controllers:
SAC the name of the SAC, determined automatically by the storage
adapter hardware.
Configured Devices (group: n, module: n)
Slot for internal disks, this is the slot number of the device. For 45xx
disks and tape drives, this is the slot number of the storage
adapter controlling the device. This value is determined
automatically from the physical location of the hardware.
Type the configured device type of the device, determined by the
physical device installed.
Name the configured name of the device. The name for a disk includes
a suffix that denotes the path used by the disk.
Primary CPU
Backup CPU
the configured primary and backup processors for the device.
Device Target ID the configured ID of the device.
Lun the logical unit number of the device.
STORAGE - Info ADAPTER \COMM.$ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
Location Access List
(11,1,50) 0,1