SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)

Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem529937-008
11- 5
Displaying Storage Adapter Configuration
Information
Example of a Detailed INFO IOMF ADAPTER Report
-> INFO ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50, DETAIL
This report shows that the storage adapter in an IOMF CRU:
Has mirrored disks on SAC 1 and SAC 2
Has an Open SCSI device on SAC 3
See Explanation of Fields on page 11-4.
Example of an INFO SNDA ADAPTER Report
-> INFO ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
This report shows that the storage adapter is accessed by processors 0 through 15.
STORAGE - Detailed Info ADAPTER \COMM.$ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
Access List................... 0,1
Location (Group,Module,Slot).. (11,1,50)
ServerNet Addressable Controllers:
SAC \COMM.$ZZSTO.#IOMF.SAC-1.GRP-11.MOD-1.SLOT-50:
Configured Devices ( group: 11, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID Lun
2 DISK $ESD001-MB 0 1 4 0
4 DISK $ESD002-MB 0 1 5 0
6 DISK $D11105-MB 0 1 8 0
8 DISK $MAIL-MB 0 1 9 0
12 DISK $P1D04-MB 0 1 0 0
14 DISK $P5D04-MB 0 1 1 0
16 DISK $P6D04-MB 0 1 2 0
18 DISK $D11117-MB 0 1 3 0
SAC \COMM.$ZZSTO.#IOMF.SAC-2.GRP-11.MOD-1.SLOT-50:
Configured Devices ( group: 11, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID Lun
1 DISK $ESD001-P 0 1 4 0
3 DISK $ESD002-P 0 1 5 0
5 DISK $D11105-P 0 1 8 0
7 DISK $MAIL-P 0 1 9 0
11 DISK $P1D04-P 0 1 0 0
13 DISK $P5D04-P 0 1 1 0
15 DISK $P6D04-P 0 1 2 0
17 DISK $D11117-P 0 1 3 0
SAC \COMM.$ZZSTO.#IOMF.SAC-3.GRP-11.MOD-1.SLOT-50:
Configured Devices ( group: 11, module: 1 ):
Slot Type Name Primary Backup Device
CPU CPU Target ID
50 SCSI $L700C16-P 1 0 0
STORAGE - Info ADAPTER \COMM.$ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
Location Access List
(11,1,51) 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15