Displaying Storage Adapter Status Information
To display status of the 6760 ServerNet device adapter in group 11, slot 51:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
The display is shown and explained under Example of a STATUS SNDA
ADAPTER Report on page 11-13.
To display detailed status of the same 6760 ServerNet device adapter:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51, DETAIL
The display is shown and explained under Example of a Detailed STATUS SNDA
ADAPTER Report on page 11-14.
Example of a STATUS PMF ADAPTER Report
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
STORAGE - Status ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Location Status POST Power-1 Power-2 SACs
(1,1,50) PRESENT PASSED ON ON 3
Explanation of Fields
Location the physical location of the adapter (group, module, slot).
Status shows whether the adapter is present.
POST shows whether the power-on self-test (POST) passed.
Power-1 shows whether power rail 1 has power on.
Power-2 shows whether power rail 2 has power on.
SACs the number of SACs present in the adapter (three SACs for a PMF
CRU or IOMF CRU, up to four SACs for a ServerNet/DA).