SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)

Configuring and Managing ServerNet Storage
Adapters
SCF Reference Manual for the Storage Subsystem529937-008
11-12
Displaying Storage Adapter Status Information
Example of a Detailed STATUS IOMF ADAPTER Report
-> STATUS ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50, DETAIL
See Explanation of Fields on page 11-10.
STORAGE - Detailed Status ADAPTER \COMM.$ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
Adapter Type..... IOMF
Location......... (11,1,50) Number of SACs... 3
Part ID.......... 129574 POST Result...... PASSED
Power-1.......... ON Power-2.......... ON
Revision Level... A10-15 Status........... PRESENT
Tracking Number.. G23LAJ Vendor ID........
ServerNet Addressable Controllers:
SAC \COMM.$ZZSTO.#IOMF.SAC-1.GRP-11.MOD-1.SLOT-50:
SAC Number..... 1 Firmware.......... T1067AAO
POST Result.... PASSED SAC SSCI ID....... 6
SAC Type....... SCSI Side.............. X-Fabric
Status......... PRESENT
Configured Devices ( group: 11 , module: 1 ):
Slot Name State Substate Primary Backup
PID PID
2 $ESD001-MB STARTED 0,292 1,275
4 $ESD002-MB STARTED 0,293 1,274
6 $D11105-MB STOPPED HARDDOWN 0,289 1,278
8 $MAIL-MB STARTED 0,296 1,271
12 $P1D04-MB STARTED 0,299 1,268
14 $P5D04-MB STARTED 0,300 1,267
16 $P6D04-MB STARTED 0,301 1,265
18 $D11117-MB STOPPED HARDDOWN 0,290 1,277
SAC \COMM.$ZZSTO.#IOMF.SAC-2.GRP-11.MOD-1.SLOT-50:
SAC Number..... 2 Firmware.......... T1067AAO
POST Result.... PASSED SAC SSCI ID....... 6
SAC Type....... SCSI Side.............. X-Fabric
Status......... PRESENT
Configured Devices ( group: 11 , module: 1 ):
Slot Name State Substate Primary Backup
PID PID
1 $ESD001-P *STARTED 0,292 1,275
3 $ESD002-P *STARTED 0,293 1,274
5 $D11105-P STOPPED HARDDOWN 0,289 1,278
7 $MAIL-P *STARTED 0,296 1,271
11 $P1D04-P *STARTED 0,299 1,268
13 $P5D04-P *STARTED 0,300 1,267
15 $P6D04-P *STARTED 0,301 1,265
17 $D11117-P STOPPED HARDDOWN 0,290 1,277
SAC \COMM.$ZZSTO.#IOMF.SAC-3.GRP-11.MOD-1.SLOT-50:
SAC Number..... 3 Firmware.......... T1067AAO
POST Result.... PASSED SAC SSCI ID....... 6
SAC Type....... SCSI Side.............. X-Fabric
Status......... PRESENT
Configured Devices ( group: 11 , module: 1 ):
Slot Name State Substate Primary Backup
PID PID
50 $L700C16-P *STARTED 1,282 0,286