Displaying Storage Adapter Status Information
Example of a Detailed STATUS FCSA ADAPTER Report
-> status adapter $ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1, DETAIL
STORAGE - Detailed Status ADAPTER \IO.$ZZSTO.#FCSA.GRP-11.MOD-2.SLOT-1
Adapter Type..... FCSA
Flash Boot....... T0612G06 Flash Update Active.... Done
Flash Firmware... T0630G06 Flash Update Result.... Init
Location......... (11,2,1) Number of SACs......... 2
Part ID.......... 526217-001 POST Result............ PASSED
Power-1.......... ON Power-2................ ON
Revision Level... A01-01 Status................. PRESENT
Tracking Number.. MP0008 Vendor ID..............
ServerNet Addressable Controllers:
SAC \IO.$ZZSTO.#FCSA.SAC-1.GRP-11.MOD-2.SLOT-1:
SAC Number..... 1 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... F port Node Name......... 20060B00001CE5F8
Port Id........ 65792 Port Name......... 50060B00001CE5F8
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
1 $PT00-B STARTED 2,272 3,264
1 $PT01-B STARTED 3,283 2,273
1 $PT02-B STARTED 3,282 2,274
SAC \IO.$ZZSTO.#FCSA.SAC-2.GRP-11.MOD-2.SLOT-1:
SAC Number..... 2 Firmware.......... T0630G06
POST Result.... PASSED SAC SCSI ID.......
SAC Type....... FC Side.............. Both
Status......... PRESENT
Connection..... Loop Node Name......... 20060B00001CE5FA
Port Id........ 1 Port Name......... 50060B00001CE5FA
SAC State...... Ready SAC Subtype....... 1
Configured Devices ( group: 11, module: 2 ):
Slot Name State Substate Primary Backup
PID PID
1 $PT00-M *STARTED 2,272 3,264
1 $PT01-M *STARTED 3,283 2,273
1 $PT02-M *STARTED 3,282 2,274
Explanation of Fields
Flash Boot is the name of the flash boot file.
Firmware is the name of the flash firmware file
Flash Update Active indicates the status of the flash update operation
Flash Update Result indicates the state resulting from the flash update operation
ServerNet Addressable Controllers:
Connection indicates the Fibre Channel connections type.