ADD TAPE Command
DEVICEID number
is the device ID of the tape drive.
This value must match either the SCSI ID of the tape drive (if SCSI-connected) or
the device ID of the tape drive (if Fibre Channel connected).
If the tape drive is connected to a PMF CRU, an IOMF CRU, or an SNDA, number
is in the range 0 through 5. The default is 5.
If the tape drive is connected to an F-SAC of an SNDA, number is 4 or 5.
HIGHPIN { ON | OFF }
specifies whether the IOP can run at a high PIN (ON, the default) or only at a low
PIN (OFF).
LOCATION ( group, module, slot )
is the location of the adapter where the tape drive is connected. This attribute is
required.
LUN number
is the logical unit number (LUN) used by the path of the tape volume in the range 0
through 31.
MAXOPENS number
is the maximum concurrent opens allowed for the device. number is in the range
1 through 64. The default is 4.
PORTNAME number
is the Fibre Channel port name used by the path to a tape volume. The number
should be entered as a 16 character hexadecimal number, without a leading %H.
PRIMARYCPU number
is the processor in which the primary IOP starts. If you omit this attribute, the
processor is automatically chosen based on the physical location of the device.
PROGRAM [[$vol.]subvol.]fileid
is the object file name of the IOP. If not specified, PROGRAM is:
$SYSTEM.SYSTEM.OTPPROCP
If you specify PROGRAM as $SYSTEM.SYSTEM, the operating system first
searches for the file on $SYSTEM.SYSTEM and on the current SYSnn