SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)
Storage Subsystem Commands
SCF Reference Manual for the Storage Subsystem—529937-008
14-63
ALTER SUBSYS Command
ALTER SUBSYS Command
The ALTER SUBSYS command changes attributes of the storage subsystem manager.
The syntax is:
Wild card characters are not supported.
OUT file-spec
directs all SCF output to the specified file.
SUBSYS $ZZSTO
is the storage subsystem manager.
attribute-spec
is one or more ALTER SUBSYS Attributes.
ALTER SUBSYS Attributes
[ , AUTOCONFIGURE { ON | OFF } ]
[ , AUTOREVIVE { ON | OFF } ]
[ , AUTOSTART { ON | OFF } ]
[ , BULKIO { ON | OFF } ]
[ , LABELTAPE { ON | OFF } ]
[ , UPS { ON | OFF } ]
AUTOCONFIGURE { ON | OFF }
specifies whether the storage subsystem performs automatic configuration of
nonconfigured internal storage devices when they are discovered.
For information about using this attribute, see Automating Disk Configuration on
page 6-6.
AUTOREVIVE { ON | OFF }
(mirrored disks only) specifies whether to automatically start a revive operation on
a mirrored volume either when a new disk is inserted or when the system is loaded
and a mirrored volume is not synchronized.
ALTER [ / OUT file-spec / ] SUBSYS $ZZSTO
[ , attribute-spec ]...
ON Enables automatic configuration.
OFF Disables automatic configuration (default).
ON Automatically starts a revive operation using the values for the
REVIVEPRIORITY and REVIVERATE attributes.
OFF Does not automatically start a revive operation (default).