Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem—529937-008
B-39
Storage Subsystem Error Messages
Recovery. Start the FCSMON processes. If they are already running, wait 3 minutes
and re-try the command.
00110
Cause. The alternate path (BACKUP or MBACKUP) SAC is not connected to the
same device as the corresponding primary path (PRIMARY or MIRROR).
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command with corrected path attributes.
00111
Cause. FCSMON process returned an error.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Contact your service representative.
00112
Cause. The Pool name along with the system name exceeded the 16 character
maximum. The Pool name is limited to less than or equal to 6 chars when the system
name is 7 characters
Effect. Alter Disk, Pool fails. SCF waits for the next command.
Recovery. 1. Delete the Pool name and add a new Pool name with six or less
characters. 2. Reissue the Alter Disk, Pool command for the desired disks.
01001
volname
is the name of the volume that you specified in the command.
Cause. One of the magnetic disks of a mirrored volume is not current with the other
magnetic disk. A disk revive operation is required.
STORAGE E00110 Alternate path SAC is not connected to the
same device.
STORAGE E00111 FCSMON process returned an error.
STORAGE E00112 The Pool name length along with the system
name exceeds 16 chars.
STORAGE 01001 Must perform disk revive: volname