Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem529937-008
B-44
Storage Subsystem Error Messages
2. Remove the command from the SCF command file.
01012
volname
is the name of the volume that you specified in the command.
Cause. You issued the CONTROL DISK, REPLACEBOOT command in noninteractive
mode. The CONTROL DISK, REPLACEBOOT command is available only in
interactive mode. In interactive mode, you are prompted to verify the operation.
Effect. The REPLACEBOOT operation is not performed. SCF waits for the next
command.
Recovery.
1. Start SCF and reissue the command from the SCF prompt.
2. Remove the command from the SCF command file.
01013
Cause. You issued the CONTROL DISK, REPLACEBOOT command in noninteractive
mode. The CONTROL DISK, REPLACEBOOT command is available only in
interactive mode. In interactive mode, you are prompted to verify the operation.
Effect. The REPLACEBOOT operation is not performed. SCF waits for the next
command.
Recovery.
1. Start SCF and reissue the command from the SCF prompt.
2. Remove the command from the SCF command file.
01014
sectoraddress
is the address of the sector that you attempted to spare.
STORAGE 01012 The CONTROL DISK, REPLACEBOOT operation will
OVERWRITE the existing bootstrap on volname.
STORAGE 01013 The CONTROL DISK, REPLACEBOOT operation can
leave one of the disk paths in a HARDDOWN substate.
STORAGE 01014 LSA sectoraddress passed controller
defectiveness testing and was not spared.