SCF Reference Manual for the Storage Subsystem (G06.27+, H06.04+)

Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem529937-008
B-58
Storage Subsystem Error Messages
Cause. You have not used the REPLACE command from interactive mode.
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the REPLACE command from an interactive prompt.
01054
command
is the SCF command that you issued.
devname
is the name of the device you specified in the command.
Cause. You attempted to add a device that requires a cable configuration that is not
possible, given the other devices using the same ServerNet addressable controller
(SAC).
Effect. The command is not executed. SCF waits for the next command.
Recovery. Reissue the command, specifying a different value for the SAC or the
corresponding backup SAC.
01055
command
is the SCF command that you issued.
devname
is the name of the device you specified in the command.
attribute
is the attribute that you specified with an invalid value.
Cause. You attempted to decrease the value of an attribute while the I/O process is in
a STARTED state.
Effect. The command is not executed. SCF waits for the next command.
STORAGE 01054 command devname failed. Impossible, 3-cable
configuration implied by other devices using the same SAC.
STORAGE 01055 command devname failed. Attribute cannot be
decreased while devname is in a STARTED state.