Storage Subsystem Error Messages
SCF Reference Manual for the Storage Subsystem529937-008
B-59
Storage Subsystem Error Messages
Recovery. Either:
Correct the value for the indicated attribute.
Place the I/O process in a STOPPED state and reissue the command.
01056
Cause. You specified primary and mirror paths to a device on the same chain. This
configuration is not recommended.
Effect. The command is executed. This is a warning.
Recovery. Specify the two paths on different chains.
01057
Cause. You requested changes to mirror-related configuration attributes of a disk
volume that is in a started state.
Effect. All configuration attributes that are not related to the mirror configuration of the
disk volume has been completed.
Recovery. None. A subsequent message will inform you about the effect of the action
and ask you whether to continue.
01058
Cause. You are about to power off a storage device.
Effect. The storage device will be powered off and will not be accessible for
informational commands such as the STATUS command.
Recovery. Respond “Y” to the prompt requesting approval to do changes online. If
you do not want to power off the storage device, enter "N" to the prompt.
STORAGE W01056 The primary and mirror paths to a device
should be on different chains.
STORAGE W01057 All configuration changes except those related
to the mirror configuration have been performed for the disk
volume.
STORAGE W01058 This action will cause the device to be
inaccessible to the system.