SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
 ServerNet Addressable Controllers:
 SAC \COMM.$ZZSTO.#IOMF.SAC-1.GRP-11.MOD-1.SLOT-50:
 Configured Devices ( group: 11, module: 1 ):
 Slot Type Name Primary Backup Device 
 CPU CPU Target ID Lun
 2 DISK $ESD001-MB 0 1 4 0
 4 DISK $ESD002-MB 0 1 5 0
 6 DISK $D11105-MB 0 1 8 0
 8 DISK $MAIL-MB 0 1 9 0
 12 DISK $P1D04-MB 0 1 0 0
 14 DISK $P5D04-MB 0 1 1 0
 16 DISK $P6D04-MB 0 1 2 0
 18 DISK $D11117-MB 0 1 3 0
 SAC \COMM.$ZZSTO.#IOMF.SAC-2.GRP-11.MOD-1.SLOT-50:
 Configured Devices ( group: 11, module: 1 ):
 Slot Type Name Primary Backup Device 
 CPU CPU Target ID Lun
 1 DISK $ESD001-P 0 1 4 0
 3 DISK $ESD002-P 0 1 5 0
 5 DISK $D11105-P 0 1 8 0
 7 DISK $MAIL-P 0 1 9 0
 11 DISK $P1D04-P 0 1 0 0
 13 DISK $P5D04-P 0 1 1 0
 15 DISK $P6D04-P 0 1 2 0
 17 DISK $D11117-P 0 1 3 0
 SAC \COMM.$ZZSTO.#IOMF.SAC-3.GRP-11.MOD-1.SLOT-50:
 Configured Devices ( group: 11, module: 1 ):
 Slot Type Name Primary Backup Device 
 CPU CPU Target ID
 50 SCSI $L700C16-P 1 0 0
This report shows that the storage adapter in an IOMF CRU:
• Has mirrored disks on SAC 1 and SAC 2
• Has an Open SCSI device on SAC 3
See Explanation of Fields - Detailed INFO PMF ADAPTER Report.
Example of an INFO SNDA ADAPTER Report
-> INFO ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51 
STORAGE - Info ADAPTER \COMM.$ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
 Location Access List
 (11,1,51) 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
This report shows that the storage adapter is accessed by processors 0 through 15.
See Explanation of Fields — Detailed INFO PMF ADAPTER Report.
Example of a Detailed INFO SNDA ADAPTER Report
-> INFO ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51, DETAIL 
STORAGE - Detailed Info ADAPTER \COMM.$ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
 Access List................... 0,1,2,3,4,5,6,7,8,9,10,11,12,13,14,15
 Location (Group,Module,Slot).. (11,1,51)
 ServerNet Addressable Controllers:
 SAC \COMM.$ZZSTO.#SNDA.SAC-1.GRP-11.MOD-1.SLOT-51:
156 Configuring and Managing ServerNet Storage Adapters