SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50, DETAIL
The display is shown and explained under “Example of a Detailed STATUS PMF ADAPTER
Report” (page 158).
To display status of the adapter in the IOMF CRU in group 11, slot 50:
-> STATUS ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50
The display is shown and explained under “Example of a STATUS IOMF ADAPTER Report”
(page 160).
To display detailed status of the same adapter in the IOMF CRU:
-> STATUS ADAPTER $ZZSTO.#IOMF.GRP-11.MOD-1.SLOT-50, DETAIL
The display is shown and explained under “Example of a Detailed STATUS IOMF ADAPTER
Report” (page 160).
To display status of the 6760 ServerNet device adapter in group 11, slot 51:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51
The display is shown and explained under “Example of a STATUS SNDA ADAPTER Report”
(page 161).
To display detailed status of the same 6760 ServerNet device adapter:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-11.MOD-1.SLOT-51, DETAIL
The display is shown and explained under “Example of a Detailed STATUS SNDA ADAPTER
Report” (page 161).
Example of a STATUS PMF ADAPTER Report
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
STORAGE - Status ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Location Status POST Power-1 Power-2 SACs
(1,1,50) PRESENT PASSED ON ON 3
Explanation of Fields STATUS PMF ADAPTER Report
The physical location of the adapter (group, module, slot).Location
Shows whether the adapter is present.Status
Shows whether the power-on self-test (POST) passed.POST
Shows whether power rail 1 has power on.Power-1
Shows whether power rail 2 has power on.Power-2
The number of SACs present in the adapter (three SACs for a PMF CRU or IOMF CRU, up to four
SACs for a ServerNet/DA).
SACs
Example of a Detailed STATUS PMF ADAPTER Report
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50, DETAIL
STORAGE - Detailed Status ADAPTER \COMM.$ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
Adapter Type..... PMF
Location......... (1,1,50) Number of SACs... 3
Part ID.......... 142184 POST Result...... PASSED
Power-1.......... ON Power-2.......... ON
Revision Level... A03-05 Status........... PRESENT
Tracking Number.. G25XC8 Vendor ID........
ServerNet Addressable Controllers:
SAC \COMM.$ZZSTO.#PMF.SAC-1.GRP-1.MOD-1.SLOT-50:
158 Configuring and Managing ServerNet Storage Adapters