SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
OUT file-spec
directs all SCF output to the specified file.
ADAPTER $ZZSTO.#type.GRP-g.MOD-m.SLOT-s
is a ServerNet adapter of type PMF, IOMF, or SNDA. g cannot have a leading zero.
DETAIL
displays detailed status information.
FIRMWARE
displays only the firmware currently running in each SAC.
SACS
displays detailed status for SACs but does not list devices. See “Example of a STATUS FCSA
ADAPTER, SACS” (page 162).
SERVERNET
displays only the status of the adapter’s ServerNet paths. This attribute applies only to Fibre
Channel ServerNet adapters (FCSAs). See “Example of a STATUS FCSA ADAPTER, SERVERNET
Report” (page 164).
VPROCS
displays only the full VPROC strings for firmware. See “Example of a STATUS FCSA ADAPTER,
VPROCS Report” (page 164).
STATUS ADAPTER Examples
• To display the status of the PMF CRU adapter in group 01, slot 50:
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50
See the display and explanation under “Example of a STATUS PMF ADAPTER Report”
(page 158).
• To display detailed status of the PMF CRU adapter in group 01, slot 50:
-> STATUS ADAPTER $ZZSTO.#PMF.GRP-1.MOD-1.SLOT-50, DETAIL
See the display and explanation under “Example of a Detailed STATUS PMF ADAPTER Report”
(page 158).
• To display the status of the 6760 ServerNet device adapter in group 01, slot 53:
-> STATUS ADAPTER $ZZSTO.#SNDA.GRP-1.MOD-1.SLOT-53
See the display and explanation under “Example of a STATUS SNDA ADAPTER Report”
(page 161).
STATUS CLIM Command
The STATUS command displays current storage status information about CLIM objects. The syntax
is:
STATUS [ / OUT file-spec / ] CLIM $ZZSTO.clim-name
, { DETAIL | SERVERNET }
| ENCRYPTION | KEYMANAGER
Wild-card characters are supported.
OUT file-spec
directs all SCF output to the specified file.
CLIM $ZZSTO.clim-name
is the name of the CLIM to display.
280 Storage Subsystem Commands