SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

cmd
is the command that you issued.
Cause
You issued a RESET, FORCED command, which stops and restarts the I/O process. You can use
this command only in interactive mode.
Effect
The I/O process is restarted if you acknowledge the verification request.
Recovery
Informational message only; no corrective action is required.
00047
STORAGE 00047 CPUs not running.
Cause
You issued a START or PRIMARY command targeting a processor or set of processors that were
not running.
Effect
The command is not executed.
Recovery
Reload the processors or change the configuration and reissue the command.
00048
STORAGE 00048 Required adapter not present for location.
Cause
You issued an ADD or ALTER command, specifying a location that does not have its corresponding
adapters installed.
Effect
The command is not executed.
Recovery
Correct the command to use locations that are available.
00049
STORAGE 00049 Command failed.
Cause
The command failed because of an internal error. The storage subsystem manager experienced
an error condition while accessing a helper server.
Effect
The command is not executed.
Recovery
Restart the storage subsystem manager and retry the command. If the problem persists, contact
your service provider.
00050
STORAGE 00050 command failed. POOL argument error: errnum
command
is the command you specified.
errnum
is the POOL argument error number.
Storage Subsystem Error Messages 311