SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Cause
The indicated SAC did not pass the power-on self-test (POST).
Effect
The command is not executed.
Recovery
Contact your service provider. See “If You Have to Contact Your Service Provider” (page 298).
00067
STORAGE 00067 cmd failed. Mismatched SAC type in sacpath.
cmd
is the command you specified.
sacpath
is the path of the ServerNet addressable controller (SAC) specified in the command.
Cause
The type of the SAC specified in the command does not match the SAC type in the PRIMARYSAC
location.
Effect
The command is not executed.
Recovery
Resolve the cause of the failure and reissue the command.
00068
STORAGE 00068 cmd failed. Wrong CRU type for device in sacpath.
cmd
is the command you specified.
sacpath
is the path of the ServerNet addressable controller (SAC) specified in the command.
Cause
The device type of the device specified in the command does not match the device type of the
primary device.
Effect
The command is not executed.
Recovery
Verify the device specified in the command is the same type as the primary device. (For example,
you are trying to mirror an internal disk with a 45xx disk.) Then, reissue the command.
00069
STORAGE 00069 cmd failed. sacpath violates IOP placement.
cmd
is the command you specified.
sacpath
is the path of the ServerNet addressable controller (SAC) specified in the command.
Cause
The indicated command specified a combination of paths and processors that is not supported
by the I/O process (IOP).
Effect
The command is not executed.
316 Storage Subsystem Error Messages