SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Recovery
Resolve the cause of the failure and reissue the command.
00074
STORAGE 00074 Operation invalid, REPLACE already committed.
Cause
You issued a REPLACE command twice.
Effect
The command is not executed.
Recovery
Use the REVERT operation to back out of the committed replace.
00075
STORAGE 00075 REPLACE DISK volname failed to delete software replacement record, error err-num.
volname
is the disk name you specified.
err-num
is the file-system error that occurred. For more information, refer to the Guardian Procedure
Errors and Messages Manual.
Cause
A file-system error occurred while data was being deleted from $SYSTEM.SYSnn.CONFALT.
Effect
The command is not executed.
Recovery
Retry the command. If the problem persists, contact your service provider. See “If You Have to
Contact Your Service Provider” (page 298).
00076
STORAGE 00076 REPLACE operation already pending for device.
Cause
You issued a REPLACE command to a device that is already performing a replace operation.
Effect
The command is not executed.
Recovery
Follow these steps:
1. Wait for the operation to finish.
2. If it does not finish, retry the operation with the REPLACE, AGAIN command.
3. If the problem persists, contact your service provider. See “If You Have to Contact Your
Service Provider” (page 298).
00077
STORAGE 00077 REPLACE DISK volname software replacement record read, error: err-num.
volname
is the disk name you specified.
err-num
is the file-system error that occurred. For more information, refer to the Guardian Procedure
Errors and Messages Manual.
Cause
A file-system error occurred while data was being read from $SYSTEM.SYSnn.CONFALT.
318 Storage Subsystem Error Messages