SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Recovery
1. Verify that the VPROC program:
Resides on the system disk
Is executable
2. Verify that the object you are using for the REPLACE, PROGRAM command is compatible
with the running object.
00091
STORAGE 00091 Unsupported program version.
Cause
You issued a REPLACE command, and one of two problems occurred:
The program file used for this command did not contain the expected version of the
procedure.
The version of the procedure did not indicate that it supported this command.
Effect
The command is not executed.
Recovery
1. Contact your service provider. See “If You Have to Contact Your Service Provider (page 298).
2. Obtain a new program file from your service provider.
3. Retry the command.
00092
STORAGE 00092 Unexpected error returned from CONFIG_GETINFO_, the IOP did not respond
within the allocated timeout period.
Cause
An IOP did not respond within the timeout period, so CONFIG_INFO_ returned an unexpected
error.
Effect
The command is not executed.
Recovery
1. Retry the command.
2. If the problem persists, contact your service provider. See “If You Have to Contact Your
Service Provider” (page 298).
00093
STORAGE 00093 No attributes have been specified for this command.
Cause
When you entered the command, you did not enter any attributes.
Effect
The command is not executed.
Recovery
Enter the desired parameters. Retry the command.
00094
STORAGE 00094 Both paths of the disk process are assigned the same fabric.
Cause
When you entered the command, you assigned the same fabric to access both paths to the disk.
Storage Subsystem Error Messages 323