SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)
Effect
The command is executed. This is a warning.
Recovery
Reissue the command and assign a separate path to each path.
00095
STORAGE 00095 Unable to process the command due to an internal NSC error.
Cause
The command resulted in an internal NonStop C (NSC) language module error.
Effect
The command is not executed.
Recovery
1. Retry the command.
2. If the problem persists, contact your service provider. See “If You Have to Contact Your
Service Provider” (page 298).
00096
STORAGE E00096 Unable to perform n of the requested path switches: process-path-list
Cause
A SWITCH ADAPTER command returned a count (n) of the number of paths that did not switch,
along with a list of the unswitched paths.
Effect
The command is not executed.
Recovery
Handle those exceptions individually.
00097
STORAGE E00097 Unable to perform n of the requested IOP primary changes: process-list
Cause
A PRIMARY SUBSYS command returned a count (n) of the number of IOPs that did not move to
the other processor, along with a list of those IOPs.
Effect
The command is not executed.
Recovery
Handle those exceptions individually.
00098
STORAGE W00098 Action begun successfully, but not yet finished. Monitor with STATUS.
Cause
The action was initiated successfully, but it has not yet finished.
Effect
The command is executed. This message is only a reminder.
Recovery
Use the STATUS command to monitor the progress of the action.
00099
STORAGE E00099 The process cannot be terminated.
324 Storage Subsystem Error Messages