SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

00109
STORAGE E00109 Can't access fiber because no FCSMON processes are assigned.
Cause
No FCSMON processes are running, or they have not yet been assigned to monitor the specified
SAC.
Effect
The command is not executed.
Recovery
Start the FCSMON processes. If they are already running, wait 3 minutes and re-try the command.
00110
STORAGE E00110 Alternate path SAC is not connected to the same device.
Cause
The alternate path (BACKUP or MBACKUP) SAC is not connected to the same device as the
corresponding primary path (PRIMARY or MIRROR).
Effect
The command is not executed.
Recovery
Reissue the command with corrected path attributes.
00111
STORAGE E00111 FCSMON process returned an error.
Cause
FCSMON process returned an error.
Effect
The command is not executed.
Recovery
Contact your service representative.
00112
STORAGE E00112 The Pool name length along with the system name exceeds 16 chars.
Cause
The Pool name along with the system name exceeded the 16 character maximum. The Pool
name is limited to less than or equal to 6 chars when the system name is 7 characters
Effect
Alter Disk, Pool fails.
Recovery
1. Delete the Pool name and add a new Pool name with six or less characters. 2. Reissue the
Alter Disk, Pool command for the desired disks.
00113
STORAGE E00113 The two paths to a device must use different CLIMs.
Cause
You have placed both paths to a device through the same CLIM. This is not allowed.
Effect
The command is not executed.
Recovery
Place the two paths through different CLIMs.
Storage Subsystem Error Messages 327