SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Recovery
Log on as a member of the SECURITY-ENCRYPTION-ADMIN (65536) group.
00126
STORAGE E00126 This command requires an encryption license.
Cause
This command requires an encryption license.
Effect
The command is not executed.
Recovery
Install an NSVLE license file. Use STATUS SUBSYS command to verify that there is a valid license
file installed on the NonStop system.
00127
STORAGE E00127 Filesystem error during encryption command.
Cause
File system error on the license file or SSH communication files.
Effect
The command is not executed.
Recovery
Make sure the license file, SSH and SCP are correct.
00128
STORAGE E00128 The specified device is not CLIM-connected.
Cause
The specified device is not CLIM-connected, so encryption commands can't be performed on it.
Effect
The command is not executed.
Recovery
No action is required.
00129
STORAGE E00129 Old lunmgr on this CLIM does not support encryption or partition.
Cause
lunmgr on this CLIM does not support encryption or partition.
Effect
The command is not executed.
Recovery
Install a newer version of CLIM software.
00130
STORAGE E00130 CLIMCMD returned an error.
Cause
To resolve an SSH error, the Storage Subsystem Manager ($ZZSTO) executed a CLIMCMD
command, but it did not succeed.
Effect
The command is not executed.
330 Storage Subsystem Error Messages