SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Recovery
Install a newer version of lunmgr on this CLIM.
1. Make sure SSH can communicate with the CLIM.
2. Run any CLIMCMD command manually for the same CLIM, which may also help to resolve
this issue. If any error is reported by CLIMCMD, correct this problem and re-issue the
command.
-> CLIMCMD S1002531 pwd
00134
STORAGE E00134 Device WWN mismatch between PRIMARYLUN and BACKUPLUN.
Cause
For a PARTITION command, the device WWN of the PRIMARYLUN and the BACKUPLUN does
not match.
Effect
The command is not executed.
Recovery
Make sure that correct values of CLIM and LUN are specified and reissue the command.
00135
STORAGE E00135 Partition count or partition entry mismatch between the PRIMARYCLIM
and the BACKUPCLIM.
Cause
Partition count or partition entry mismatch occurred between the PRIMARYCLIM and the
BACKUPCLIM.
Effect
The command is not executed.
Recovery
Make sure that the configuration for CLIM and LUN are correct and reissue the command.
00136
STORAGE E00136 LUN is already being used as an unpartitioned disk volume.
Cause
For an ADD PARTITION command, the LUN specified is already being used as an unpartitioned
disk volume.
Effect
The command is not executed.
Recovery
Delete the NonStop configuration of the unpartitioned disk and retry the operation.
00137
STORAGE E00137 Disk volume paths to the partition are in STARTED state.
Cause
For a DELETE PARTITION command, the disk volume has paths to the partition in STARTED state.
Effect
The command is not executed.
Recovery
Stop the disk paths to the partition and retry the operation.
Storage Subsystem Error Messages 331