SCF Reference Manual for the Storage Subsystem (G06.28+, H06.05+, J06.03+)

Effect
The command is not executed.
Recovery
Specify the correct source and target devices and reissue the command.
00143
STORAGE E00143 The number of disks that require WRITECACHE ENABLE
or DISABLE exceeds the limit.
Cause
The changing of the WRITECACHE ENABLE or DISABLE affects more than the limit number of
disks.
Effect
The command is not executed.
Recovery
Simplify the disk configurations so the chain of mirrored disk partitions involves fewer disks.
00145
STORAGE E00145 Invalid lunmgr response from the CLIM.
Cause
The lunmgr response from the CLIM is in an invalid format.
Effect
The command is not executed. SCF waits for the next command.
Recovery
1. Run any CLIMCMD command manually for the same CLIM. If any error is reported by
CLIMCMD, correct this problem and re-issue the command.
2. If the problem persists, contact your service provider. See “Upgrade and Replacement
Procedures” (page 362) for additional information.
00146
STORAGE E00146 Cannot enable WRITECACHE for the volume due to the disk type
in primary or mirror location.
Cause
Trying to enable WRITECACHE on a disk type that does not support this feature. Only CLIM
SAS disks support enabling of WRITECHACE.
Effect
The request is not processed.
Recovery
This command cannot be performed on the specified disk type. If WRITECACHE was previously
enabled on this disk, disable WRITECACHE using ALTER DISK, WRITECACHE command.
00147
STORAGE E00147 The disk process is in SOFTDOWN state which prevents
command execution.
Cause
Either primary and backup DP2 (the disk process) are in SOFTDOWN state or DP2 is in
SOFTDOWN state.
Effect
The command is not executed. SCF waits for the next command.
Storage Subsystem Error Messages 333